The blower and propane solenoids are working fine and i m getting a 63 65 volt reading on the igniter wire using a digital voltmeter with the igniter wire connected at both ends.
Rv furnace igniter not clicking.
The ducts carry the heated air from the furnace to the interior of the rv.
If the furnace is in warranty then you will get it.
A good way to test this out is to run the blower blower is apt to operate fine under 10 5 v if the blower runs then that means the battery supply may be under 10 5 v and thus its not able to open the furnace valve.
Atwood furnace won t ignite.
The problem is when the blower works and the heater doesn t ignite it is the board inside heater it will have to be pulled out and replaced it is inside your heater unit chances are if you were at a camp site and you didn t have a device to control spikes it zapped your igniter board.
This is pretty standard and it only requires putting in a new fuse.
So let s review the do s and don ts.
Rv furnace igniter not working.
This is typically the problem if you can hear your furnace click on but it does not fire up.
This happens when the spark igniter try s to ignite the pilot light but fails.
The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite.
Rv furnace operates with a 10 5 v supply and at times if the battery is not able provide above 10 5v then the furnace wont ignite.
This has to be fixed and its a good idea to take technical help here.
Rv furnace blowing fuses.
Otherwise your furnace won t start.
Forest river rv model.
This is nothing but a ignition system failure.
I have a 2001 teton with an atwood model 8531 iv dclp that won t ignite.
When winter arrives most service calls i get are for furnace repair.
In other words there s an ignition system malfunction that needs to be fixed.
The furnace may make a click sound but it wont start.
The exhaust is an air outlet on the exterior of the rv that exhausts the gases produced during the combustion process the gases are a combination of carbon dioxide and carbon.
But there will be times when the furnace will blow a freshly replaced fuse as well.
Sure enough the clicking would stop.
The dsi is an acronym direct spart ignition it s an electronic igniter that uses a spark ignites the gas air mix.
If that happens something else might.
First of all not knowing what you are doing with a gas fired appliance can be dangerous no matter how easy it looks on youtube.
Knowledge of multi meter use is essential.
A faulty or dirty ignition or sensor is a relatively easy fix so follow these steps and you may be able to solve the problem yourself.